Operating rooms (ORs), operating theatres

Why pressure monitoring is critical:
In operating rooms, air quality and cleanliness are essential to prevent infections during surgery. To maintain sterility, positive pressure is required. This ensures that clean, filtered air flows outword from the operating room into adjacent areas, such as airlocks and corridors — preventing unfiltered air from entering the operating room.

In operating rooms, maintaining a stable pressure cascade is essential to uphold sterility and prevent airborne contamination. Even a slight drop in positive pressure can cause unfiltered air from adjacent spaces to enter the OR, directly increasing the risk of surgical site infections.

To safeguard the sterile field, continuous differential pressure monitoring is indispensable. It allows technical staff and infection prevention teams to detect deviations in real time and take corrective action before conditions become critical.

The ATM420 supports this process by delivering precise, real-time monitoring with clear audiovisual alarms. It helps ensure compliance with international standards like DIN 1946-4, ISO 14644, and hospital hygiene protocols — forming a reliable layer of defense in the infection control strategy.

For technical managers and infection control officers alike, pressure monitoring is not just a regulatory requirement — it’s essential for safeguarding patients.

Why Choose the ATM420:

  • Continuous monitoring of differential pressure between:
    • Corridor and anteroom/airlock (measured by one differential pressure transmitter)
    • Corridor and isolation room (measured by second differential pressure transmitter)
  • Immediate visual feedback with clear green = safe and red = alarm indicators.
  • Optional audible alarm with adjustable time delay, preventing unnecessary alarms when doors briefly open.
  • Optional slave display inside the airlock, allowing staff to check room status before entering the OR.
  • Maintenance / cleaning mode – Activated via a secure code, the display switches to grey, indicating the system is temporarily paused. This mode is ideal during cleaning, calibration, or system maintenance.
  • Easy to install and intuitive to use – designed for both technical staff and healthcare personnel.
  • Fully compatible with Building Management Systems (BMS) for centralized monitoring and data logging.
  • Equipped with high accuracy differential pressure transmitters that offer two standard analog outputs (4…20mA and 0…10V), allowing seamless connection to variable air volume controllers (VAV) or Building Automation Systems (BAS).
  • Optional Modbus RTU output for advanced integration — monitor display status remotely and even adjust alarm settings from your central system.
ATM420 gives surgical teams real-time feedback on room pressure — ensuring a sterile and safe environment.